  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "An update is available that resolves publicly reported vulnerabilities in the product versions listed as affected in the advisory.\n\nAn attacker who successfully exploited these vulnerabilities could\n\n- allow arbitrary files to be deleted with system privileges (CVE-2026-81572),\n\n- read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573),\n\n- crash CodeMeter and disclose sensitive information such as process memory and stack canaries (CVE-2026-81574),\n\n- crash CodeMeter (CVE-2026-81575), or\n\n- read potentially sensitive license information (CVE-2026-81576)",
        "title": "Summary"
      },
      {
        "category": "other",
        "text": "For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:\n\n– Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and separate them from any general-purpose network (e.g. office or home networks).\n\n– Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.\n\n– Never connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for.\n\n– Scan all data imported into your environment before use to detect potential malware infections.\n\n– Minimize network exposure for all applications and endpoints to ensure that they are not accessible from the Internet unless they are designed for such exposure and the intended use requires such.\n\n– Ensure all nodes are always up to date in terms of installed software, operating system, and firmware patches as well as anti-virus and firewall.\n\n– When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n",
        "title": "General security recommendations"
      },
      {
        "category": "other",
        "text": "For additional instructions and support please contact your local ABB service organization. For contact information, see www.abb.com/contactcenters.\n\nInformation about ABB’s cyber security program and capabilities can be found at www.abb.com/cybersecurity.\n",
        "title": "Support"
      },
      {
        "category": "legal_disclaimer",
        "text": "The information in this document is subject to change without notice, and should not be construed as a commitment by ABB.\n\nABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages.\n\nThis document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\n\nAll rights to registrations and trademarks reside with their respective owners.\n",
        "title": "Notice"
      },
      {
        "category": "other",
        "text": "ABB has a rigorous internal cyber security continuous improvement process which involves regular testing with industry leading tools and periodic assessments to identify potential product issues. Occasionally an issue is determined to be a design or coding flaw with implications that may impact product cyber security.\n\nWhen a potential product vulnerability is identified or reported, ABB immediately initiates our vulnerability handling process. This entails validating if the issue is in fact a product issue, identifying root causes, determining what related products may be impacted, developing a remediation, and notifying end users and governmental organizations.\n\nThe resulting Cyber Security Advisory intends to notify customers of the vulnerability and provide details on which products are impacted, how to mitigate the vulnerability or explain workarounds that minimize the potential risk as much as possible. The release of a Cyber Security Advisory should not be misconstrued as an affirmation or indication of an active threat or ongoing campaign targeting the products mentioned here. If ABB is aware of any specific threats, it will be clearly mentioned in the communication.\n\nThe publication of this Cyber Security Advisory is an example of ABB’s commitment to the user community in support of this critical topic. Responsible disclosure is an important element in the chain of trust we work to maintain with our many customers. The release of an Advisory provides timely information which is essential to help ensure our customers are fully informed.\n",
        "title": "Purpose"
      },
      {
        "category": "faq",
        "text": "What causes the vulnerability?\n- Refer to section “Vulnerability severity and details“.\n\nWhat is Wibu CodeMeter?\n- Wibu CodeMeter is a technology of Wibu-Systems providing secure protection and effective license management of software and digital content. \n\nWhat are the affected ABB tools (Automation Builder, Drive Application Builder, Virtual Drive, Virtual DrivePlus)?\n- All mentioned tools are using Wibu CodeMeter for implementation of license enforcement:\n   - Automation Builder is the programming and commissioning tool mainly for the ABB PLC AC500 and the operator panels CP600.\n   - Drive Application Builder is the programming and commissioning tool ABB’s IEC programmable Drives (mainly ACS880 series).\n   - Virtual Drive enhances Drive Composer Pro by enabling offline configuration of ABB drives without requiring physical hardware. Supported drives include ACS380, ACS380-E, ACS480, ACS580 and ACS880 primary control program.\n   - ACS880 Virtual DrivePlus is a digital twin of ACS880 product series, running on a desktop in virtual time and designed for high-fidelity EMT (Electromagnetic Transient) simulations of a drive or drive systems.\n\nWhat might an attacker use the vulnerability to do?\n- An attacker who successfully exploited these vulnerabilities could\n   - allow arbitrary files to be deleted with system privileges (CVE-2026-81572),\n   - read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573),\n   - crash CodeMeter and disclose sensitive information such as process memory and stack canaries (CVE-2026-81574),\n   - crash CodeMeter (CVE-2026-81575), or\n   - read potentially sensitive license information (CVE-2026-81576).\n\nHow could an attacker exploit the vulnerability?\n- Refer to section “Vulnerability severity and details“.\n\nCould the vulnerability be exploited remotely?\n- Yes, an attacker who has network access to an affected system node could exploit the vulnerabilities. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed.\n\nWhen this security advisory was issued, had this vulnerability been publicly disclosed?\n- Yes, the vulnerabilities have been publicly disclosed.\n\nWhen this security advisory was issued, had ABB received any reports that this vulnerability was being exploited?\n- No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued",
        "title": "Frequently asked questions"
      }
    ],
    "publisher": {
      "category": "vendor",
      "name": "ABB PSIRT",
      "namespace": "https://www.abb.com/global/en/company/about/cybersecurity/alerts-and-notifications"
    },
    "references": [
      {
        "category": "self",
        "summary": "ABB CYBERSECURITY ADVISORY - PDF version ",
        "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011572&LanguageCode=en&DocumentPartId=&Action=Launch"
      },
      {
        "category": "self",
        "summary": "ABB CYBERSECURITY ADVISORY - CSAF version ",
        "url": "https://psirt.abb.com/csaf/2026/3adr011572.json"
      },
      {
        "summary": "Local Privilege Escalation in CodeMeter Runtime on Windows\n",
        "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-103081.pdf"
      },
      {
        "summary": "Vulnerabilities in CodeMeter Runtime If Configured as Server\n",
        "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-103401.pdf"
      }
    ],
    "title": "Automation Builder, Drive Application Builder, Virtual Drive, Virtual DrivePlus Impacted by multiple vulnerabilities in Wibu CodeMeter",
    "tracking": {
      "current_release_date": "2026-09-03T00:30:00.000Z",
      "generator": {
        "date": "2026-09-03T14:42:22.541Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.6.11"
        }
      },
      "id": "3ADR011572",
      "initial_release_date": "2026-09-03T00:30:00.000Z",
      "revision_history": [
        {
          "date": "2026-09-03T00:30:00.000Z",
          "legacy_version": "A",
          "number": "1",
          "summary": "Initial version."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": ">2.10.0",
                "product": {
                  "name": "ABB Automation Builder >2.10.0",
                  "product_id": "AV1"
                }
              }
            ],
            "category": "product_name",
            "name": "Automation Builder"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "/all",
                "product": {
                  "name": "ABB Drive Application Bulder /all",
                  "product_id": "AV2"
                }
              }
            ],
            "category": "product_name",
            "name": "Drive Application Bulder"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": ">1.5.1",
                "product": {
                  "name": "ABB Virtual Drive >1.5.1",
                  "product_id": "AV3"
                }
              },
              {
                "category": "product_version",
                "name": "1.5.1",
                "product": {
                  "name": "ABB Virtual Drive 1.5.1",
                  "product_id": "FX1"
                }
              }
            ],
            "category": "product_name",
            "name": "Virtual Drive"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": ">1.70",
                "product": {
                  "name": "ABB Virtual Drive Plus >1.70",
                  "product_id": "AV4"
                }
              }
            ],
            "category": "product_name",
            "name": "Virtual Drive Plus"
          }
        ],
        "category": "vendor",
        "name": "ABB"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2026-81572",
      "cwe": {
        "id": "CWE-284",
        "name": "Improper Access Control"
      },
      "notes": [
        {
          "category": "description",
          "text": "cmu.exe --create-io --file C: creates a predictable temporary file under C:\\CM-Stick. The directory and file paths are not properly checked for NTFS reparse points, such as junctions or symbolic links, before file operations are performed. A local attacker can create a junction at the temporary file that points to an arbitrary system path. Because CodeMeter Runtime runs with System privileges, this could allow arbitrary files to be deleted with System privileges and potentially enable local privilege escalation. ",
          "title": "CVE description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1"
        ],
        "known_affected": [
          "AV1",
          "AV2",
          "AV3",
          "AV4"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD -CVE-2026-81572",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81572"
        }
      ],
      "remediations": [
        {
          "category": "workaround",
          "details": "For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts.\n\nFor CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network\nserver functionality at some point but no longer need it, disable it:\n\n - Open the Registry Editor and navigate to Computer\\HKEY_LOCAL_MACHINE\\SOFTWARE\\ WIBUSYSTEMS\\CodeMeter\\Server\\CurrentVersion\\, then change the value of IsNetworkServerfrom 1 to 0.\n\n - Restart CodeMeter.\n",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "mitigation",
          "details": "Refer to section “General security recommendations” for further advise on how to keep your system secure.",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The problem is corrected by Wibu in the following product versions:\n - CodeMeter Runtime 8.41a\n - CodeMeter Runtime 9.10\n\nABB recommends that customers apply the update at earliest convenience. Both versions are available\nfor download from the Wibu download site and can be updated independent of the tool installation:\nhttps://www.wibu.com/support/user/user-software.html\n\nAn updated version of CodeMeter Runtime containing the fixes will be integrated into the following tool\nversions:\n - Automation Builder: Version 2.10.0 (expected by Q1/2027)\n - Drive Application Bulder: not planned, will be transferred to the Classic lifecycle phase end of\nQ3/2026\n - Virtual Drive: Version 1.5.1\n -  Virtual DrivePlus: Version 1.70 (expected by Q4/2026)",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "environmentalScore": 8.2,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "reportConfidence": "CONFIRMED",
            "scope": "UNCHANGED",
            "temporalScore": 8.2,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "title": "CVE-2026-81572"
    },
    {
      "cve": "CVE-2026-81573",
      "cwe": {
        "id": "CWE-59",
        "name": "Improper Link Resolution Before File Access ('Link Following')"
      },
      "notes": [
        {
          "category": "description",
          "text": "If CodeMeter Runtime is configured as a server, the configuration command handler does not enforce networkorigin restrictions. Commands intended only for local or same-network clients can therefore be executed by arbitrary remote peers. An attacker can read potentially sensitive configuration data and overwrite selected values in Server.ini. This does include the hash of the credentials for the CodeMeter WebAdmin, enabling WebAdmin takeover.\n\nCodeMeter Runtime is only affected by the vulnerabilities listed below if it is configured as a server. This is not the default. To verify the setting, check the profiling value IsNetworkServer:\n - IsNetworkServer=1: configured as a server (affected).\n - IsNetworkServer=0: not configured as a server.\n",
          "title": "CVE description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1"
        ],
        "known_affected": [
          "AV1",
          "AV2",
          "AV3",
          "AV4"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD -CVE-2026-81573",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81573"
        }
      ],
      "remediations": [
        {
          "category": "workaround",
          "details": "For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts.\n\nFor CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network\nserver functionality at some point but no longer need it, disable it:\n\n - Open the Registry Editor and navigate to Computer\\HKEY_LOCAL_MACHINE\\SOFTWARE\\ WIBUSYSTEMS\\CodeMeter\\Server\\CurrentVersion\\, then change the value of IsNetworkServerfrom 1 to 0.\n\n - Restart CodeMeter.\n",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "mitigation",
          "details": "Refer to section “General security recommendations” for further advise on how to keep your system secure.",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The problem is corrected by Wibu in the following product versions:\n - CodeMeter Runtime 8.41a\n - CodeMeter Runtime 9.10\n\nABB recommends that customers apply the update at earliest convenience. Both versions are available\nfor download from the Wibu download site and can be updated independent of the tool installation:\nhttps://www.wibu.com/support/user/user-software.html\n\nAn updated version of CodeMeter Runtime containing the fixes will be integrated into the following tool\nversions:\n - Automation Builder: Version 2.10.0 (expected by Q1/2027)\n - Drive Application Bulder: not planned, will be transferred to the Classic lifecycle phase end of\nQ3/2026\n - Virtual Drive: Version 1.5.1\n -  Virtual DrivePlus: Version 1.70 (expected by Q4/2026)",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "environmentalScore": 8.6,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "reportConfidence": "CONFIRMED",
            "scope": "UNCHANGED",
            "temporalScore": 8.6,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "title": "CVE-2026-81573"
    },
    {
      "cve": "CVE-2026-81574",
      "cwe": {
        "id": "CWE-134",
        "name": "Use of Externally-Controlled Format String"
      },
      "notes": [
        {
          "category": "description",
          "text": "The logger does not sanitize input strings in certain cases, allowing an attacker to inject printf-style format specifiers. This can be used to reliably crash CodeMeter and disclose sensitive information such as process memory and stack canaries. The attack works locally, for example by using cmu --set-proxy to set the proxy value, and remotely when combined with CVE-2026-81573 by setting General.ProxyServer and then triggering this vulnerability.\n\nCodeMeter Runtime is only affected by the vulnerabilities listed below if it is configured as a server. This is not the default. To verify the setting, check the profiling value IsNetworkServer:\n\n - IsNetworkServer=1: configured as a server (affected).\n - IsNetworkServer=0: not configured as a server",
          "title": "CVE description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1"
        ],
        "known_affected": [
          "AV1",
          "AV2",
          "AV3",
          "AV4"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD -CVE-2026-81574",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81574"
        }
      ],
      "remediations": [
        {
          "category": "workaround",
          "details": "For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts.\n\nFor CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network\nserver functionality at some point but no longer need it, disable it:\n\n - Open the Registry Editor and navigate to Computer\\HKEY_LOCAL_MACHINE\\SOFTWARE\\ WIBUSYSTEMS\\CodeMeter\\Server\\CurrentVersion\\, then change the value of IsNetworkServerfrom 1 to 0.\n\n - Restart CodeMeter.\n",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "mitigation",
          "details": "Refer to section “General security recommendations” for further advise on how to keep your system secure.",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The problem is corrected by Wibu in the following product versions:\n - CodeMeter Runtime 8.41a\n - CodeMeter Runtime 9.10\n\nABB recommends that customers apply the update at earliest convenience. Both versions are available\nfor download from the Wibu download site and can be updated independent of the tool installation:\nhttps://www.wibu.com/support/user/user-software.html\n\nAn updated version of CodeMeter Runtime containing the fixes will be integrated into the following tool\nversions:\n - Automation Builder: Version 2.10.0 (expected by Q1/2027)\n - Drive Application Bulder: not planned, will be transferred to the Classic lifecycle phase end of\nQ3/2026\n - Virtual Drive: Version 1.5.1\n -  Virtual DrivePlus: Version 1.70 (expected by Q4/2026)",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "environmentalScore": 8.2,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "reportConfidence": "CONFIRMED",
            "scope": "UNCHANGED",
            "temporalScore": 8.2,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "title": "CVE-2026-81574"
    },
    {
      "cve": "CVE-2026-81575",
      "cwe": {
        "id": "CWE-130",
        "name": "Improper Handling of Length Parameter Inconsistency"
      },
      "notes": [
        {
          "category": "description",
          "text": "If configured as a server, CodeMeter Runtime accepts requests with opcode 0x5e, which contain the data length and the data itself. Missing bounds checking on the data length value can lead to out of bounds reads, causing a segmentation fault that ultimately crashes the CodeMeter Runtime.\n\nCodeMeter Runtime is only affected by the vulnerabilities listed below if it is configured as a server. This is not the default. To verify the setting, check the profiling value IsNetworkServer:\n\n - IsNetworkServer=1: configured as a server (affected).\n - IsNetworkServer=0: not configured as a server.",
          "title": "CVE description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1"
        ],
        "known_affected": [
          "AV1",
          "AV2",
          "AV3",
          "AV4"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD -CVE-2026-81575",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81575"
        }
      ],
      "remediations": [
        {
          "category": "workaround",
          "details": "For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts.\n\nFor CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network\nserver functionality at some point but no longer need it, disable it:\n\n - Open the Registry Editor and navigate to Computer\\HKEY_LOCAL_MACHINE\\SOFTWARE\\ WIBUSYSTEMS\\CodeMeter\\Server\\CurrentVersion\\, then change the value of IsNetworkServerfrom 1 to 0.\n\n - Restart CodeMeter.\n",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "mitigation",
          "details": "Refer to section “General security recommendations” for further advise on how to keep your system secure.",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The problem is corrected by Wibu in the following product versions:\n - CodeMeter Runtime 8.41a\n - CodeMeter Runtime 9.10\n\nABB recommends that customers apply the update at earliest convenience. Both versions are available\nfor download from the Wibu download site and can be updated independent of the tool installation:\nhttps://www.wibu.com/support/user/user-software.html\n\nAn updated version of CodeMeter Runtime containing the fixes will be integrated into the following tool\nversions:\n - Automation Builder: Version 2.10.0 (expected by Q1/2027)\n - Drive Application Bulder: not planned, will be transferred to the Classic lifecycle phase end of\nQ3/2026\n - Virtual Drive: Version 1.5.1\n -  Virtual DrivePlus: Version 1.70 (expected by Q4/2026)",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "environmentalScore": 7.5,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "reportConfidence": "CONFIRMED",
            "scope": "UNCHANGED",
            "temporalScore": 7.5,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "title": "CVE-2026-81575"
    },
    {
      "cve": "CVE-2026-81576",
      "cwe": {
        "id": "CWE-639",
        "name": "Authorization Bypass Through User-Controlled Key"
      },
      "notes": [
        {
          "category": "description",
          "text": "If configured as a server, CodeMeter Runtime issues handles per connection and relies on a cryptographically weak SID as sole authenticator. An attacker can brute-force the SID, recover another session's handle number, and read license information belonging to another handle.\n\nCodeMeter Runtime is only affected by the vulnerabilities listed below if it is configured as a server. This is not the default. To verify the setting, check the profiling value IsNetworkServer:\n\n - IsNetworkServer=1: configured as a server (affected).\n - IsNetworkServer=0: not configured as a server",
          "title": "CVE description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1"
        ],
        "known_affected": [
          "AV1",
          "AV2",
          "AV3",
          "AV4"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD -CVE-2026-81576",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81576"
        }
      ],
      "remediations": [
        {
          "category": "workaround",
          "details": "For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts.\n\nFor CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network\nserver functionality at some point but no longer need it, disable it:\n\n - Open the Registry Editor and navigate to Computer\\HKEY_LOCAL_MACHINE\\SOFTWARE\\ WIBUSYSTEMS\\CodeMeter\\Server\\CurrentVersion\\, then change the value of IsNetworkServerfrom 1 to 0.\n\n - Restart CodeMeter.\n",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "mitigation",
          "details": "Refer to section “General security recommendations” for further advise on how to keep your system secure.",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The problem is corrected by Wibu in the following product versions:\n - CodeMeter Runtime 8.41a\n - CodeMeter Runtime 9.10\n\nABB recommends that customers apply the update at earliest convenience. Both versions are available\nfor download from the Wibu download site and can be updated independent of the tool installation:\nhttps://www.wibu.com/support/user/user-software.html\n\nAn updated version of CodeMeter Runtime containing the fixes will be integrated into the following tool\nversions:\n - Automation Builder: Version 2.10.0 (expected by Q1/2027)\n - Drive Application Bulder: not planned, will be transferred to the Classic lifecycle phase end of\nQ3/2026\n - Virtual Drive: Version 1.5.1\n -  Virtual DrivePlus: Version 1.70 (expected by Q4/2026)",
          "product_ids": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 7.7,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "reportConfidence": "CONFIRMED",
            "scope": "CHANGED",
            "temporalScore": 7.7,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2",
            "AV3",
            "AV4"
          ]
        }
      ],
      "title": "CVE-2026-81576"
    }
  ]
}